logo
player background
live avator

5s
Total
0
Today
0
Total
0
Today
0
  • What would you like to know?
    Company Advantages Sample Service Certificates Logistics Service
Online Chat WhatsApp Inquiry
Auto
resolution switching...
Submission successful!
bandiera bandiera
Dettagli sulle notizie
Created with Pixso. Casa Created with Pixso. Notizie Created with Pixso.

Perforated, Plated or Clad: Five Nickel Strips Compared

Perforated, Plated or Clad: Five Nickel Strips Compared

2026-10-28

Five strip products turn up in the same request for quotation often enough that buyers treat them as grades of one material: nickel plated steel, nickel plated copper, copper nickel clad, perforated pure nickel, and perforated pure copper. They are not grades of one material. They differ on three independent axes, and a quotation that compares them on price alone compares almost nothing.

The first axis is where the nickel sits: through the whole section, as a coating a few micrometres thick, or as a bonded layer taking a share of the thickness. The second is the base metal underneath, because steel, copper and nickel conduct and corrode very differently. The third is whether the strip carries holes, which is the axis most often left out of the comparison and the one that changes the most.

Perforation is not a weight saving exercise. It removes conducting section, it concentrates stress at every hole edge, and it cuts through whatever surface protection the material had. That last effect is the subject of this article, because it decides which of the five can be perforated at all in a corrosive joint, and which ones fail first at the hole wall.

Nickel Strips

Three Axes, Not One Ranking

The table below separates the five forms by structure. Read the fourth and fifth columns together: conductivity comes from the base metal, while corrosion behaviour at a cut edge comes from what the cut exposes.

Form Nickel position Base metal Conductivity, approx. What a cut edge exposes
Nickel plated steel strip Coating, 1 to 5 micrometres Low carbon steel Below 15 % IACS Bare steel at every cut face
Nickel plated copper strip Coating, 1 to 3 micrometres Copper Above 96 % IACS Bare copper at every cut face
Copper nickel clad strip Bonded layer, 10 % to 30 % of thickness Copper with a nickel face 77 % to 92 % IACS A laminate cross section, both metals visible
Perforated pure nickel strip Full section Nickel About 25 % IACS before perforation Nickel, the same metal as the surface
Perforated pure copper strip None Copper About 100 % IACS before perforation Copper, the same metal as the surface

Only two of the five expose the same metal at a cut edge as they show on the face. The other three change character the moment a tool cuts them, and a punched strip is nothing but cut edges repeated several thousand times per metre.

This is why a specification written for solid strip does not transfer to perforated strip. A plated strip qualified on a flat coupon has been tested on its coating. The same strip, punched, presents bare substrate around every hole, and the corrosion test that passed the coupon says nothing about the hole wall.

The Hole Costs Current in Proportion to Open Area

Open area is the fraction of the strip surface removed by the holes. Because the holes run through the full thickness, the conducting section falls by the same fraction, and the resistance rises by the reciprocal.

A strip at 40 % open area keeps 60 % of its conducting section, so its resistance is 1 divided by 0.6, which is 1.67 times the solid value. At 60 % open area the multiplier is 2.5. The arithmetic is simple, and it is the first thing a drawing should state, because open area is often chosen for fluid passage or weight and its electrical cost is discovered later.

Open area Section retained Resistance multiplier Equivalent conductivity, pure copper Equivalent conductivity, pure nickel
0 % 100 % 1.00 100 % IACS 25 % IACS
20 % 80 % 1.25 80 % IACS 20 % IACS
40 % 60 % 1.67 60 % IACS 15 % IACS
60 % 40 % 2.50 40 % IACS 10 % IACS

Two corrections belong with that table. First, the multiplier assumes current flows uniformly across the width, which holds when the hole pattern is fine and evenly distributed. A coarse pattern with wide unperforated margins carries current in the margins and the local resistance is lower than the average suggests, at the cost of a hot spot where the pattern begins.

Second, open area does not account for the hole edge itself. A punched hole has a rollover, a shear band and a burr, and the burr side has a slightly larger effective diameter in the current path while being the place where coating damage starts. Etched strip has tapered walls and no burr, and laser cut strip has a heat affected rim. The three processes are not interchangeable at the same nominal open area.

Why Punch Holes At All

Five reasons justify perforation, and each points to a different pattern.

Fluid or electrolyte passage is the reason in battery and filtration work. The hole is a channel, so the pattern follows the flow direction and the open area is set by how much the process needs, not by weight.

Weight reduction matters in moving parts and in large area shields, where the strip is a conductor and a support at the same time. Here the open area can be high, and the electrical penalty is accepted.

Multi point contact is the reason in grounding and gasket applications. Many small contacts in parallel give a lower and more stable interface resistance than one large contact, because a single oxide patch or a single high spot no longer sets the whole joint.

Stress relief and keying appear in laminated and stacked assemblies, where the holes let resin, adhesive or a fastener pass through, or allow the strip to expand without buckling.

Access for welding is the fifth, and it is often the real reason a perforated strip is specified. A hole next to a weld spot lets the electrode reach through a stack, or vents gas that would otherwise blow the nugget apart.

What Each Hole Wall Exposes

This is where the five forms separate in a way no grade change can fix. The table describes the cut face, since the surface is the part a sample shows.

Form Condition at the hole wall What happens in service Practical mitigation
Nickel plated steel Bare steel, no coating, full thickness Steel is anodic to nickel, so a rust ring forms at each hole and grows under the coating Seal or re plate after punching, or move to a clad or solid product
Nickel plated copper Bare copper at the wall Copper oxidises, and the nickel around the hole acts as a small anode in electrolyte Accept where dry; avoid in salt spray or electrolyte contact
Copper nickel clad Both layers visible on the wall Copper is exposed along the wall, with a nickel face on one side only Orient the nickel face to the corrosive side and keep the wall dry
Perforated pure nickel Nickel, identical to the surface No dissimilar couple and no coating to breach; wastage is uniform Specify burr height and edge finish, the wall is not the weak point
Perforated pure copper Copper, identical to the surface Corrosion resistance is low, but there is no galvanic cell at the edge Use where conductivity dominates and the environment is controlled

The steel case is the most severe and the most common. Nickel plated steel is the standard material for pocket plate battery electrodes precisely because it is cheap, formable, and weldable, and the perforation is functional. The same perforation puts bare steel in contact with electrolyte at every hole, so the plate lives or dies by how well that cut face is protected. Post punching re plating, edge sealing, or a deliberate choice of a thicker coating with a formed edge are the usual answers.

The clad case is subtler and often misread. A clad strip has no coating to breach, so it survives handling and abrasion far better than plated strip. Once punched, however, the wall is a laminate cross section: the nickel face is still nickel, while the wall and the opposite face are copper. Orienting the nickel face toward the electrolyte or the humid side preserves most of the benefit. Orienting it the other way throws the advantage away without changing the price.

The pure nickel case is the one that does not need mitigation. The cut face is the same alloy as the surface, at the same composition and the same corrosion potential, so there is no couple, no undercutting and no coating integrity question. That is the specific reason perforated pure nickel strip is chosen in alkaline electrolyte, in filter media that see aggressive fluids, and in electrodes where the cut edge sits in the working environment. Its conductivity is roughly a quarter of copper, which is the price paid for that uniformity.

Pure copper perforated strip sits at the other end. It is the best conductor of the five and has no edge couple, and it has almost no corrosion resistance of its own. It belongs in grounding, shielding, and dry current collection, where the environment is controlled and the joint is protected by housing or by plating after assembly.

Strength Falls Faster Than Conductivity

Open area and strength loss are not the same number, and the gap between them is set by how the holes are arranged.

Conductivity is an average: current spreads across the full width, so the conducting fraction equals the solid fraction, one minus open area. Tension is not an average. It is carried by the narrowest continuous section across the width, and in a pattern with aligned rows that section is a single row of ligaments.

Take round holes on a square pitch at 40 % open area. The hole diameter works out at about 0.71 of the pitch, so a row of ligaments retains roughly 29 % of the full width. Conductivity retains 60 %. The strip has lost 40 % of its conductance and 71 % of its tensile capacity, and both numbers come from the same pattern.

Pattern at 40 % open area Critical section across the width Tensile capacity, approx. Conductance retained
Aligned rows, square pitch One row of ligaments, about 29 % 29 % of solid strip 60 %
Staggered rows, 60 degree pitch Two rows share the path, roughly half again 45 % to 55 % of solid strip 60 %
Wide unperforated margins Margin width governs, pattern adds little Set by margin, often 50 % or more 60 % average, lower in perforated zone

The practical conclusion is that a perforated strip should be designed for its mechanical duty first. If the joint has to carry load or survive vibration, staggered rows with generous margins are worth the small loss in open area. If the strip only conducts and lets fluid through, aligned rows with a high open area are cheaper to tool.

There is a second mechanical effect at the hole edge itself. A circular hole in a loaded strip raises local stress by a factor of roughly 2 to 3, and a row of holes approaches the upper end. Under vibration or repeated bending this is where a crack starts, at the burr side first because the burr is a notch within a notch. This is why a perforated strip that passes a static tensile test can still fail in a vibrating assembly within weeks.

Where Each One Wins

The five forms sort cleanly by application once the axes are fixed. The table below is a starting point, not a rule; the environment and the assembly method override it.

Application Usual first choice Reason
Battery cell tab and module connector Copper nickel clad or nickel plated copper Conductance from copper, weld window from the nickel face
Pocket plate alkaline electrode Perforated nickel plated steel, or perforated pure nickel where life dominates Steel for cost and formability, nickel where the cut edge sits in electrolyte
Grounding and earthing strap Perforated pure copper Highest conductance, multi point contact, dry environment
EMI shield and gasket core Nickel plated copper, plated steel for cost Contact resistance and spring properties
Filtration of aggressive fluid Perforated pure nickel The cut edge is the working surface and must be the same alloy
Electrolyser and fuel cell current collector Perforated pure nickel Alkaline or oxidizing service with holes through the section
Decorative and trim parts Nickel plated steel Cost, formability, appearance

Two entries deserve a comment because they are usually decided on price and later regretted. The pocket plate electrode is the classic case: nickel plated steel is the standard, and the perforation is what makes the plate work, yet the same perforation is what limits its life. Moving to perforated pure nickel multiplies the material cost and removes the failure mode. Where the plate is replaced on a schedule that is short enough, steel is the rational choice.

The current collector case runs the other way. In an electrolyser the strip is perforated for gas and liquid transport, sits in alkaline electrolyte, and carries current at the same time. A plated product puts bare substrate in the electrolyte at every hole, and a clad product puts copper there. Only a solid nickel section survives that combination, which is why perforated pure nickel holds this application despite a quarter of copper conductivity.

What to Specify on the Order

A perforated strip order has six specification items that a solid strip order does not, and omitting any of them leaves the supplier to choose.

Item How to write it What goes wrong without it
Form and nickel position Grade plus structure, for example clad with a stated nickel share Two suppliers quote different products under the same name
Thickness and tolerance Nominal thickness with a tolerance, measured on the solid margin Thickness read at a ligament is meaningless and disputes follow
Hole geometry Shape, diameter, pitch, arrangement, and open area as a calculated value A pattern described by pitch alone can land anywhere between 20 % and 50 % open
Burr side and height Which face carries the burr, and the limit in micrometres Stack height varies and coating damage starts on the wrong face
Temper and mechanics Tensile and elongation on the perforated strip, not on the solid coil Values taken from solid strip overstate capacity by the section ratio
Coil and edge Coil weight, bore, edge condition, camber limit Feeding jams and camber drift in automatic lines

The fourth item is the one that separates a good order from an average one. Burr is a directional feature: it forms on the exit side of the punch. Two coils punched from opposite faces look identical in a photograph and stack differently. Naming the burr face, and turning it away from the mating surface and away from the coated side, removes a whole class of assembly complaints.

The fifth item is the one most often copied from a data sheet. Tensile values published for solid strip do not apply once the strip is perforated, because the critical section has changed. A supplier who quotes the solid value is not being dishonest, merely answering the question that was asked. Ask for the value on the finished perforated strip, and ask which pattern it was measured on.

Where DLX Sits

DLX operates in Changzhou, Jiangsu, supplying nickel plated steel and copper strip, copper nickel clad strip built to a specified ratio, and perforated pure nickel and pure copper strip in coil or sheet. Hole patterns are produced to drawing, with open area, burr side and burr height stated on the certificate, and chemistry and mechanical values reported on the finished perforated material.

Four items make a quotation accurate: base form with the nickel position, thickness with tolerance, hole geometry with the calculated open area, and the burr side with its limit. Where the part goes into electrolyte or a humid assembly, say so, because that single fact decides whether a plated product is acceptable at all.

Frequently Asked Questions
Does perforating reduce conductivity by the open area?

Yes, to a first approximation. The conducting section falls by the open area fraction, so resistance rises by one divided by one minus open area. At 40 % open the multiplier is 1.67. The estimate assumes uniform current distribution, which a fine evenly spaced pattern provides.

Which of the five survives salt spray after punching?

Perforated pure nickel, because the cut face is the same alloy as the surface and there is no couple at the hole. Nickel plated steel is the weakest, since every hole exposes bare steel that is anodic to the coating. Plated copper and clad strip fall in between and depend on orientation and sealing.

Can plated strip be punched and still resist corrosion?

Only if the cut face is protected afterwards. Re plating, edge sealing, or a coating thick enough to form a continuous fillet into the hole are the usual routes. Without one of them the hole wall is bare substrate, and a salt spray result obtained on unpunched coupons does not describe the punched part.

Why is strength loss larger than the open area?

Because tension is carried by the narrowest continuous section, while current spreads across the width. At 40 % open area with aligned rows, the ligament row retains about 29 % of the width, so capacity falls by 71 % while conductance falls by 40 %. Staggering the rows recovers part of the difference.

Which way should the burr face?

Away from the mating surface and away from any coated face that will be exposed. The burr is a stress raiser and a coating damage site, so it belongs on the side that is neither loaded in contact nor visible to the environment. State the direction on the drawing, since it is invisible in a photograph.

What should a drawing for perforated strip contain?

Six items: form with nickel position, thickness with tolerance, hole geometry with calculated open area, burr side with a height limit, temper with mechanical values measured on the perforated strip, and coil plus edge requirements. Missing any one of them leaves a decision to the supplier.

Summary

The five forms separate on three axes: where the nickel sits, what the base metal is, and whether the strip carries holes. Comparing them on price alone mixes all three, which is why quotations for the same nominal strip can differ by a factor of several and all be correct.

Perforation is the axis that changes the most. It cuts conductance in proportion to open area, it cuts tensile capacity in proportion to the narrowest ligament row, and it exposes a fresh metal face at every hole. For plated and clad products that last effect is the one that decides service life, and it is decided by orientation and edge treatment as much as by grade.

Where the hole wall sits in an aggressive environment, perforated pure nickel is the only one of the five that presents the same alloy on the surface and in the hole. It pays for that with a quarter of copper conductivity. Every other choice is a trade against that reference, and the trade should be written down before the order, not discovered at the failure analysis.

References

Physical property data for copper, nickel and low carbon steel, used for the conductivity comparison.

Standard electrode potentials for copper, nickel and iron, used for the galvanic sequence at a cut edge.

Sheet metal punching practice covering rollover, shear band and burr formation, used for the hole wall description.

Definitions and geometry of perforated metal patterns, used for the open area calculation.

Stress concentration data for holes and perforated strips in tension, used for the fatigue discussion.

Construction of alkaline pocket plate electrodes on a nickel plated steel substrate, used for the electrode example.

ASTM B162, Standard Specification for Nickel Plate, Sheet and Strip, used for nickel strip grades and dimensional wording.


Conductivity and capacity figures in this article are geometric estimates: conductance from the solid fraction, tensile capacity from the critical ligament section of an idealised pattern. Real values depend on hole shape, pattern tolerance, material temper, burr condition and the test method, and they should be measured on the finished perforated strip. Corrosion behaviour at a cut edge depends on the specific electrolyte, temperature and exposure time, and a salt spray result on solid coupons does not describe a punched part. Standards are revised, and the version cited in the contract applies. This article supports material selection and enquiry, and it does not replace engineering design or incoming inspection.